INTERFAIC Engineering toolkit · Prototype

Metal weight

Section area, volume, mass and weight for common stock forms.

Geometry and loading

SCHEMATIC · NOT TO SCALE

Input parameters

Unit system

Results update as you edit.

Results

Key values (for reference)

ⓘ   Assumptions

Uniform prismatic section and constant nominal density. Sharp corners; mill tolerances, coatings and cutouts excluded. Weight uses g = 9.80665 m/s².

Equations & calculation model
V = A × L
m = ρ × V
W = m × 9.80665 m/s²

Idealised calculations for preliminary design. Check geometry, loading and boundary conditions against your application.

What it is used for

Estimating stock mass and lifting or shipping weight from nominal geometry and density.

Standards & references

OpenStax University Physics: density and mass per volume. The mass model uses volume × density. Grade-specific density presets have not been individually verified against supplier certificates; they remain typical estimates. Use certified density and actual dimensions for critical weight calculations.

Related tools and drawing guides

Section properties · Basic dimensions